CULA BESS 418kWh Liquid Cooling Battery System
High-capacity liquid cooling battery storage system for industrial and commercial applications.
AC Data
| Parameter | Value |
|---|---|
| Rated AC Power (kW) | 100 |
| Rated AC Current (A) | 144 |
| Rated AC Voltage (V) | 400V, 3P+N+PE, 50/60Hz |
| THDi | <3% (rated power) |
| Power Factor | -1 leading to +1 lagging |
Battery Energy Storage Data
| Parameter | Value |
|---|---|
| Single Cell Type | LFP 3.2V/314Ah |
| Module Combination | 1P525 |
| System Combination | 8 modules in series |
| Capacity (kWh) | 417.99 |
| Nominal Voltage (Vdc) | 1331.2 |
| Voltage Range (Vdc) | 1040~1500 |
| Charge Current | 157A / 0.5C |
| Discharge Current | 157A / 0.5C |
| Discharge Depth | 90% DoD |
| Service Life | >10,000 cycles @ 80% DoD |
| Thermal Management Mode | Liquid cooling technology |
| Thermal Runaway Management-1 | Aerosol Extinguishing or PFH |
| Thermal Runaway Management-2 | Water Immersion |
General Parameters
| Parameter | Value |
|---|---|
| Dimensions (W×D×H) (mm) | 1,300 × 1,300 × 2,340 |
| Total Weight (kg) | 3,650 |
| Operation Altitude | 3,000m (>3,000m derating) |
| Noise Level @1m | <75 dB(A) |
| IP Rating | IP55 |
| Operating Temperature | -20°C to 55°C |
| Operating Humidity (RH) | 0 to 95% |
| Storage Conditions | -20°C to 30°C, ≤95% RH, non-condensing, SoE 50% initial |
System Characteristics
| Parameter | Value |
|---|---|
| Communication Interface | CAN, RS485, Wi-Fi |
| Warranty | 10 Years |
| Certifications (pending) | UL1973 / UL9540A / IEC62477-1 / IEC61000-6-2/4 / UN3536 |
Key Features
🌡️
Independent Temperature Control
Centralized refrigeration with temperature difference ≤3°C for the container
📦
Flexible Deployment
Integrated water cooling, fire protection, and DC control system
🏗️
Three-Level Control Architecture
General Control + Master Control + Slave Control BMS architecture
🔒
System Safety
DC 5000V withstand voltage, IP68 battery box protection
📈
Capacity Upgrade
320Ah cells recommended for capacity expansion
🛡️
Long-Term Service
10,000 cycles, 10 years continuous operation
Multiple Fire Prevention
The "3 + 2ⁿ" fire prevention and control measures include:
- Module level fire protection + Container level fire protection
- Gas fire protection + Water fire protection
- Combustible gas detection + Combustible gas venting + Explosion relief